G9.17.1 How Big Is the DRAM Signal?

EasyImplementIcarus · browser samples / server checksReview the topic

Compute the bit-line signal of a DRAM read from the cell and bit-line capacitances, with and without a boosted write.

Hardware context: The 1T1C cell and bit line of a DRAM array. Estimate the read signal of a DRAM array from its cell and bit-line capacitances.

A DRAM sense amplifier needs at least 50 mV of signal. The array designer wants to know how long a bit line can be before a stored 1 no longer gives that much.

This is an Implement problem. Use charge sharing between a 20 fF cell and a bit line precharged to 900 mV. Work out three signals for a 150 fF bit line, and the largest bit line that still gives +50 mV.

Then estimate how long the cell keeps its 1 at 85 °C. Last, find the threshold shift of a programmed flash cell and its read voltage. Write each result in its assign line of the module answer. Signals can be negative.

Signals in the Timeline

SignalWidthRole
item8input of each check
Full specification
OutputMeaningUnit
dv_onebit-line change for a stored 1 of 1059 mV (no word-line boost), 150 fF bit linemV, rounded
dv_zerobit-line change for a stored 0, 150 fF bit linemV, rounded
dv_boostbit-line change for a stored 1 of 1800 mV (boosted write), 150 fF bit linemV, rounded
max_cblthe largest bit line for which a stored 1 of 1800 mV still moves the line by 50 mVfF, rounded down
dvtflash: the threshold shift, seen from the control gate, of a floating gate holding −4.5 fC behind C_CG = 3 fFmV, rounded
read_mvflash: the read voltage halfway between an erased threshold of 900 mV and the programmed onemV, rounded
ret_usretention: the time for the 20 fF cell to lose 100 mV through 3.5 pA, the leakage lesson G9.17 measured at 85 °Cµs, rounded
Worked example: 100 fF bit lineValue
transfer ratio Cs / (Cs + Cbl) = 20 / 12017 % (example_ratio)
stored 1059 mV: (1059 − 900) × 20 / 12027 mV (example_dv1)
stored 0 mV: (0 − 900) × 20 / 120-150 mV (example_dv0)

Use the charge-sharing estimate. Lesson G9.17 shows how a real access transistor changes the result.

Examples

Example 1

Worked Example: A Stored 1
Input
Cs 20 fF, Cbl 100 fF, stored 1059 mV
Output
example_dv1 = 27

159 mV above the precharge, scaled by 20 / 120: 27 mV.

Example 2

Worked Example: A Stored 0
Input
Cs 20 fF, Cbl 100 fF, stored 0 mV
Output
example_dv0 = -150

900 mV below the precharge, scaled by 20 / 120: -150 mV.

Example 3

Worked Example: The Transfer Ratio
Input
Cs 20 fF, Cbl 100 fF
Output
example_ratio = 17

Only 17 % of the cell's difference from the precharge reaches the bit line.

Constraints and Contract

  • Keep the module name answer and the names of its outputs.
  • Signals round to the nearest millivolt; max_cbl rounds down to a whole femtofarad.

Hints

Hint 1

Charge is conserved. Before: Cs × Vs + Cbl × 900 mV. After: (Cs + Cbl) × V on both.

Hint 2

The signal is V minus 900 mV, not V minus 0 V.

Hint 3

For max_cbl, solve (1800 − 900) × 20 / (20 + Cbl) = 50 for Cbl.

What the grader checks: The check reads ten outputs and compares each with the value computed in JavaScript. Three are the worked example. Lesson G9.17 compares the DRAM estimate with SPICE runs of the same 150 fF reads. It shows the flash shift on a capacitive model of a floating gate.

10 checks on Icarus · browser samples / server checks. Run the examples first, then check the full regression. Full checks use the server judge. Downloads contain public samples only. A passing result establishes the tested cases, not a proof for all possible inputs.

See all 1 steps and the final capstone

Report a problem with this page

Your code SystemVerilogSaved locally
Ln 1, Col 1Tab indents · Ctrl/⌘ + Enter runs samples
Not run yet

Worked Example: A Stored 1

Input
Cs 20 fF, Cbl 100 fF, stored 1059 mV
Expected output
example_dv1 = 27

159 mV above the precharge, scaled by 20 / 120: 27 mV.

Run samples executes all 3 public checks. Check all tests runs 10 checks on the server.

Icarus · browser samples / server checks