Fix a start-bit detector that accepts a low pulse one sample too short.
Hardware context: UART transmitter/receiver with a specified baud and sampling contract. Distinguish a low serial glitch from a qualified UART start bit.
A UART receiver kept producing bytes nobody sent. Short low noise pulses on the line looked like start bits. The detector decides too early.
A receiver samples the line 16 times per bit. A real start bit is low for 16 samples, but a glitch is shorter. So the receiver waits for eight low samples in a row before it believes a start.
The function qualify_start scans a list of samples. It returns the index of the eighth low sample in a row after a high sample, or 0xffff when there is none. The tests give it low runs of every length up to 12. Find the bug and fix it.
Signals in the Timeline
| Signal | Width | Role |
|---|---|---|
samples | 64 | input of each check |
count | 8 | input of each check |
Full specification
function automatic logic [79:0] qualify_start(input logic [63:0] samples,
input logic [7:0] count);
| Rule | Meaning |
|---|---|
| Samples | Bit i of samples is sample i. Only samples 0 to count - 1 are used. count is 0 to 64. |
| Armed | The scan starts disarmed. A high sample arms it. Low samples before the first high never count. |
| Low run | While armed, each low sample adds 1 to the run. A high sample sets the run back to 0. |
| Start | The eighth low sample of a run is the start. Return its index in bits 15:0. |
| First only | Return the first start found. Ignore any later samples. |
| None | Return 0xffff (65535) when no start is found. |
Bits 79:16 of the result are always 0. A start index says nothing about the data bits that follow.
Examples
Example 1
A Glitch, Then a Real Start- Input
count = 13; samples 0 and 4 are high, samples 1-3 and 5-12 are low
- Output
start_index = 12
The three lows at samples 1 to 3 are a glitch. The high at sample 4 sets the run back to 0. Samples 5 to 12 are eight lows in a row, so the start is at index 12.
Example 2
A Line That Is Low from the Start- Input
count = 64; all samples are low
- Output
start_index = 65535
No high sample ever arms the detector. The result is 65535, which means no start.
Example 3
Exactly Eight Lows- Input
count = 9; sample 0 is high, samples 1-8 are low
- Output
start_index = 8
The run reaches eight at sample 8, the last sample in range. The start is at index 8.
Constraints and Contract
- Samples at or above count are ignored.
- Keep the function name, the argument types and the 80-bit return type.
Hints
Hint 1
Trace one high sample followed by exactly eight lows. Which index should come back? Then try seven lows.
Hint 2
Keep the arm bit and the run counter apart. Arming needs a high sample. The run counts lows after it.
Hint 3
Look at the compare on low_count. The counter goes up before the compare, so the eighth low makes it 8.
What the grader checks: The tests cover low runs of 0 to 12 samples after 1 to 4 high samples. They also cover a line stuck low and a glitch before a start. Samples are clean 0s and 1s; no input synchronizer or noise filter is modeled.
55 checks on Icarus · browser samples / server checks. Run the examples first, then check the full regression. Full checks use the server judge. Downloads contain public samples only. A passing result establishes the tested cases, not a proof for all possible inputs.