Two views of a macro arrive from the library team. Attach the revision and complete its pin card before integration.
Hardware context: A transmitter macro and its always-on guard. Carry the isolation control across the boundary and annotate opaque pins.
Two views of a macro arrive from the library team. Attach the revision and complete its pin card before integration.
Use real set_design_attributes for the revision. Put each proposed library or port command inside draw {...}. OpenPA records this worksheet as project metadata. The simulation uses the visible island witness only.
Full specification
| Decision | Requirement |
|---|---|
| Revision | On u_tx record the project attribute macro_rev with value C. |
| Old library view | On macros/island relate pin c to power VP and ground VN with set_pin_related_supply. |
| Status output | On model island, c requests a low isolation clamp. |
| Held output | On z request the last transparent value. |
| Async control | When the latch isolation control for asynchronous set/reset asserts, z must become one. |
| Direct connection | In the opaque view the single-bit ports a and spare belong to one named feedthrough BYPASS. |
What the Grader Checks
OpenPA reads your file. A refusal ends the check with OpenPA's message and line. Otherwise every row below must pass.
| Row | Rule |
|---|---|
| Board sequence | public scenario: Run shows it |
| Board trial 1 | hidden scenario |
| Intent equals the reference | the domain of every instance; supply ports, nets and their connections; the primary supply of every domain; isolation cells (clamp, enable, sense, supply); where each isolation cell is placed; supply sets and switches; power states; level shifters; retained registers and their controls; switch names, acknowledge wires, supplies and delays |
The Design
The power-unaware RTL your UPF describes (top boundary_soc). Open a file to read it.
island.sv
module island(input logic [4:0] d, output wire a, b, c, z, spare);
assign a=d[0]; assign b=d[1]; assign c=d[2]; assign z=d[3]; assign spare=d[4];
endmodule
module boundary_soc(input logic [4:0] d, input logic iso, iso_n,
output wire a,b,c,z,spare);
island u_tx(.d(d),.a(a),.b(b),.c(c),.z(z),.spare(spare));
endmodule
Given UPF Files
Your file may load these with load_upf. The grader uses the same text.
board.upf
upf_version 4.0
set_design_top boundary_soc
create_power_domain PD_TOP -include_scope
create_power_domain PD_TX -elements {u_tx}
create_supply_port VA -direction in
create_supply_port VT -direction in
create_supply_port VG -direction in
create_supply_net NA
create_supply_net NT
create_supply_net NG
connect_supply_net NA -ports {VA}
connect_supply_net NT -ports {VT}
connect_supply_net NG -ports {VG}
create_supply_set AON -function {power NA} -function {ground NG}
create_supply_set TX -function {power NT} -function {ground NG}
associate_supply_set AON -handle PD_TOP.primary
associate_supply_set TX -handle PD_TX.primary
proc draw {line} {
set_design_attributes -elements {u_tx} -attribute [list drawing $line]
}
The Public Scenario
Board sequence. Run checks its output and shows the expected lines and any failure.
tb.sv (public scenario)
`timescale 1ns/1ps
module tb;
import UPF::*;
logic [4:0] d=5'h07; logic iso=0,iso_n=1; wire a,b,c,z,spare;
boundary_soc dut(.*);
task sample(string phase); #2; $display("%s data=%h b=%b c=%b",phase,d,b,c); endtask
initial begin
void'(supply_on("VA")); void'(supply_on("VG",0.0)); void'(supply_on("VT"));
sample("run");
sample("prepare");
void'(supply_off("VT")); sample("pause");
void'(supply_on("VT")); d=~d; sample("return");
sample("resume"); $finish;
end
endmoduleExamples
Example 1
Connected Supply Nets (Recorded)- Input
Load the supplied board file.
- OpenPA reports (recorded)
Supply network NT: port VT {port:VT net:NT fn:TX.power fn:PD_TX.primary.power}
Follow each supply port to the net it drives.
Example 2
Domain Ownership (Recorded)- Input
Load the supplied board file.
- OpenPA reports (recorded)
Power domains PD_TOP (board.upf:3): boundary_soc primary supply AON: power NA, ground NG PD_TX (board.upf:4): u_tx primary supply TX: power NT, ground NG
The two domains separate the peripheral from its powered host.
Example 3
Board Sequence (Recorded)- Input
Apply the public bench stimulus.
- The bench prints (recorded)
run data=07 b=1 c=1 prepare data=07 b=1 c=1 pause data=07 b=x c=x return data=18 b=0 c=0 resume data=18 b=0 c=0
This is the visible RTL witness. The stored pin card has no effect on these samples.
Constraints and Contract
- Load board.upf and keep its domains and wiring intact.
- Use real set_design_attributes for the revision. Put each proposed library or port command inside draw {...}. OpenPA records this worksheet as project metadata. The simulation uses the visible island witness only.
Hints
Hint 1
Start with the supplied wiring and the public stimulus.
Hint 2
On u_tx record the project attribute macro_rev with value C.
Hint 3
Compare the first changed output with the timing of its supply and control.
What the grader checks: Opaque macro annotations are graded as a drawn contract. Only visible RTL and supported UPF run.
Run checks the public scenario only and never accepts. Submit runs every row. OpenPA is our open power-aware tool: it reads the UPF, writes a power-aware copy of the RTL, and Icarus runs that copy.
See all 2 problems on this path