Rewrite an old net-based power intent file with supply sets, so that it says the same thing and runs the same way.
Hardware context: The same radio, its supplies bundled into supply sets with an n-well bias on the RF block. Name each supply once as a set, hand it to domains and strategies through handles, and check that a rewrite keeps the intent.
The power intent of pmu_soc (the design of W4.1) was written years ago in UPF 1.0 forms. Your team now writes IEEE 1801-2024. Translate it.
The power team has already put the rails into pmu_rails.upf: the ports, the nets, the switch and two supply sets. The core's set SS_CORE has no ground yet. Load that file and build the rest on it.
The translation must not change the intent. The grader compares it with the old file's domains, supplies, isolation and retention, and runs the old file's sleep and wake scenarios. The old file is the first item of the full specification.
Full specification
upf_version 1.0
set_design_top pmu_soc
# Two domains: the always-on top and the switchable core
create_power_domain PD_TOP -include_scope
create_power_domain PD_CORE -elements {u_core}
create_supply_port VDD -direction in
create_supply_port VSS -direction in
create_supply_net VDD_N
create_supply_net VSS_N
connect_supply_net VDD_N -ports {VDD}
connect_supply_net VSS_N -ports {VSS}
set_domain_supply_net PD_TOP -primary_power_net VDD_N -primary_ground_net VSS_N
# The core's supply goes through a switch that the PMU controls
create_supply_net VDD_CORE
create_power_switch SW_CORE -domain PD_CORE \
-input_supply_port {vin VDD_N} -output_supply_port {vout VDD_CORE} \
-control_port {ctrl u_pmu/pwr_en} -on_state {on vin {ctrl}} -off_state {off {!ctrl}}
set_domain_supply_net PD_CORE -primary_power_net VDD_CORE -primary_ground_net VSS_N
# Clamp the core's outputs to 0 while it is off
set_isolation ISO_CORE -domain PD_CORE -applies_to outputs -clamp_value 0 \
-isolation_power_net VDD_N -isolation_ground_net VSS_N
set_isolation_control ISO_CORE -domain PD_CORE \
-isolation_signal u_pmu/iso_en -isolation_sense high -location parent
# Keep the accumulator through power-down
set_retention RET_CORE -domain PD_CORE -elements {u_core/acc} \
-retention_power_net VDD_N -retention_ground_net VSS_N
set_retention_control RET_CORE -domain PD_CORE \
-save_signal {u_pmu/save posedge} -restore_signal {u_pmu/restore posedge}
| UPF 1.0 form in the old file | What it means |
|---|---|
| set_domain_supply_net | a domain's primary power and ground nets |
| -isolation_power_net, -isolation_ground_net | the nets that power the clamps |
| set_isolation_control | the clamp enable, its sense and where the cells go, set apart from set_isolation |
| -retention_power_net, -retention_ground_net | the nets that power the saved copy |
| set_retention_control | the save and restore signals, set apart from set_retention |
| Rule | What the grader checks |
|---|---|
| The edition | The file declares IEEE 1801-2024 (upf_version 4.0). |
| No UPF 1.0 forms | None of the five forms in the table above, and no default_isolation or default_retention handle (older UPF). |
| Build on the given file | pmu_rails.upf is loaded, and SS_CORE gets its ground there by refinement, not by a second set. |
| The same intent | Domains, supply sets, primary supplies, isolation (clamp, enable, sense, supply, placement) and retention (controls, supply) equal the old file's. |
| The same runs | The old file's sleep and wake run, and two hidden runs, print the same lines with no check firing. |
What the Grader Checks
OpenPA reads your file. A refusal ends the check with OpenPA's message and line. Otherwise every row below must pass.
| Row | Rule |
|---|---|
| Three beats, sleep, wake: the accumulator comes back | public scenario: Run shows it |
| The core is off and the bench raises en | hidden scenario |
| Two sleep and wake cycles with work between | hidden scenario |
| Intent equals the reference | the domain of every instance; supply sets and switches; the primary supply of every domain; isolation cells (clamp, enable, sense, supply); where each isolation cell is placed; retained registers and their controls; supply ports, nets and their connections |
| Edition | declares upf_version 4.0 |
| UPF forms | no set_domain_supply_net; no strategy net pairs (-isolation_power_net and the like); no set_isolation_control or set_retention_control; no default_isolation or default_retention handles; uses create_supply_set -update; uses set_isolation ISO_CORE; uses set_retention RET_CORE |
| Static report | no forbidden finding |
The Design
The power-unaware RTL your UPF describes (top pmu_soc). Open a file to read it.
pmu_soc.sv
// pmu_soc: two power domains. The top and the controller are always on; u_core can be switched off.
// The RTL is power-unaware: no isolation cell, no supply, no retention register is written here.
module pmu_soc (
input logic clk,
input logic rst_n,
input logic sleep_req,
input logic wake_req,
input logic en,
input logic [7:0] d,
input logic [1:0] rf_addr,
input logic rf_we,
output logic [7:0] total,
output logic led,
output logic [7:0] rd,
output logic [3:0] beats,
output logic [7:0] status,
output logic [2:0] pmu_state
);
logic iso_en, save, restore, pwr_en, core_rst_n;
logic [7:0] acc, rf_rd;
logic busy;
logic [3:0] core_beats;
pmu u_pmu (
.clk (clk),
.rst_n (rst_n),
.sleep_req (sleep_req),
.wake_req (wake_req),
.iso_en (iso_en),
.save (save),
.restore (restore),
.pwr_en (pwr_en),
.core_rst_n (core_rst_n),
.state_o (pmu_state)
);
core u_core (
.clk (clk),
.rst_n (core_rst_n),
.en (en),
.d (d),
.rf_addr (rf_addr),
.rf_we (rf_we),
.acc (acc),
.rf_rd (rf_rd),
.busy (busy),
.beats (core_beats)
);
// Always-on consumers of the core's outputs.
assign total = acc;
assign led = busy;
assign rd = rf_rd;
assign beats = core_beats;
// A status register: keeps the last accumulator value seen while the core was busy.
always_ff @(posedge clk or negedge rst_n)
if (!rst_n) status <= '0;
else if (busy) status <= acc;
endmodule
pmu.sv
// pmu_soc: the always-on power controller. Power-unaware RTL: it only drives control signals.
// Sleep: isolate, save, switch off. Wake: switch on, reset, restore, release isolation.
module pmu (
input logic clk,
input logic rst_n,
input logic sleep_req,
input logic wake_req,
output logic iso_en,
output logic save,
output logic restore,
output logic pwr_en,
output logic core_rst_n,
output logic [2:0] state_o
);
typedef enum logic [2:0] { RUN, ISOLATE, SAVE, OFF, PWRUP, RESET, RESTORE, RELEASE } st_e;
st_e st;
always_ff @(posedge clk or negedge rst_n)
if (!rst_n) st <= RUN;
else case (st)
RUN: if (sleep_req) st <= ISOLATE;
ISOLATE: st <= SAVE;
SAVE: st <= OFF;
OFF: if (wake_req) st <= PWRUP;
PWRUP: st <= RESET;
RESET: st <= RESTORE;
RESTORE: st <= RELEASE;
RELEASE: st <= RUN;
default: st <= RUN;
endcase
assign iso_en = (st != RUN);
assign save = (st == SAVE);
assign restore = (st == RESTORE);
assign pwr_en = !(st == OFF);
assign core_rst_n = rst_n && (st != RESET);
assign state_o = st;
endmodule
core.sv
// pmu_soc: the switchable core. An accumulator, a beat counter and a 4-word register file.
// Power-unaware RTL: nothing here knows about supplies.
module core (
input logic clk,
input logic rst_n,
input logic en,
input logic [7:0] d,
input logic [1:0] rf_addr,
input logic rf_we,
output logic [7:0] acc,
output logic [7:0] rf_rd,
output logic busy,
output logic [3:0] beats
);
logic [7:0] rf [0:3];
always_ff @(posedge clk or negedge rst_n)
if (!rst_n) begin
acc <= '0;
beats <= '0;
end else if (en) begin
acc <= acc + d;
beats <= beats + 4'd1;
end
always_ff @(posedge clk)
if (rf_we) rf[rf_addr] <= acc;
assign rf_rd = rf[rf_addr];
assign busy = en;
endmodule
Given UPF Files
Your file may load these with load_upf. The grader uses the same text.
pmu_rails.upf
# pmu_rails.upf: the rails of pmu_soc and their supply sets, from the SoC power team (given).
create_supply_port VDD -direction in
create_supply_port VSS -direction in
create_supply_net VDD_N
create_supply_net VSS_N
create_supply_net VDD_CORE
connect_supply_net VDD_N -ports {VDD}
connect_supply_net VSS_N -ports {VSS}
create_power_switch SW_CORE \
-input_supply_port {vin VDD_N} -output_supply_port {vout VDD_CORE} \
-control_port {ctrl u_pmu/pwr_en} -on_state {on vin {ctrl}} -off_state {off {!ctrl}}
create_supply_set SS_AON -function {power VDD_N} -function {ground VSS_N}
# The core's set: its ground is still to be added
create_supply_set SS_CORE -function {power VDD_CORE}
The Public Scenario
Three beats, sleep, wake: the accumulator comes back. Run checks its output and shows the expected lines and any failure.
tb.sv (public scenario)
`timescale 1ns/1ps
module tb;
import UPF::*;
logic clk = 0, rst_n = 0, sleep_req = 0, wake_req = 0, en = 0, rf_we = 0;
logic [7:0] d = 0; logic [1:0] rf_addr = 0;
wire [7:0] total, rd, status; wire led; wire [3:0] beats; wire [2:0] pmu_state;
pmu_soc dut (.*);
always #5 clk = ~clk;
task show(string what);
$display("%-12s acc=%0h total=%0h led=%0b iso=%0b pwr=%0b", what, dut.u_core.acc, total, led, dut.iso_en, dut.pwr_en);
endtask
task beats_of(input logic [7:0] x, input int n);
en = 1; d = x; repeat (n) @(posedge clk); #1 en = 0;
endtask
task sleep(); sleep_req = 1; @(posedge clk); #1 sleep_req = 0; wait (pmu_state == 3'd3); #1; endtask
task wake(); wake_req = 1; @(posedge clk); #1 wake_req = 0; wait (pmu_state == 3'd0); #1; endtask
initial begin
void'(supply_on("VDD", 1.0));
void'(supply_on("VSS", 0.0));
repeat (2) @(posedge clk);
#1 rst_n = 1;
beats_of(8'h11, 3); show("ran");
sleep(); show("asleep");
wake(); show("woken");
#20 $finish;
end
endmodule
Examples
Example 1
The Starter- Input
The starter, with the given pmu_rails.upf
- OpenPA says (recorded)
Refused: answer.upf:1: instance "pmu_soc" is in no power domain; add -include_scope to a domain at the design top, or list it in -elements
The rails load, but no instance is in a power domain yet.
Example 2
The Intent of the Old File- Input
pmu_soc_10.upf, read by OpenPA on its own (its strategies)
- OpenPA reports (recorded)
Strategies set_isolation ISO_CORE (answer.upf:24): clamp 0, enable u_pmu.iso_en active high, supply {VDD_N VSS_N}, location parent set_retention RET_CORE (answer.upf:30): u_core.acc; save u_pmu.save posedge, restore u_pmu.restore posedge; supply {VDD_N VSS_N}
Your file must build the same two strategies, with the same controls and the same always-on supply.
Example 3
The Sample Run: Three Beats, Sleep, Wake: The Accumulator Comes Back- Input
The reference file, run on the public scenario
- The bench prints (recorded)
ran acc=33 total=33 led=1 iso=0 pwr=1 asleep acc=xx total=0 led=0 iso=1 pwr=0 woken acc=33 total=33 led=0 iso=0 pwr=1
The core runs three beats of 0x11, sleeps and wakes. While it is off, its accumulator is X and total reads the clamp value 0. After wake-up the retained 0x33 is back: the same lines as the old file prints.
Constraints and Contract
- Preserve the given supply wiring and isolation placement. Add no extra supply nets or ports. No supply net may lack a source.
- Submit the whole UPF file for pmu_soc. Keep the domain and strategy names of the old file.
- Do not change pmu_rails.upf: load it as it is. A set that exists can be changed only with create_supply_set -update.
- The bench drives the supply ports VDD and VSS by name.
Hints
Hint 1
set_domain_supply_net becomes a supply set on the domain's primary handle.
Hint 2
Each strategy's net pair becomes one supply-set option, and each control command folds back into its strategy command.
Hint 3
Run the starter after each step: OpenPA names the first thing it cannot find.
What the grader checks: OpenPA reads your file and pmu_rails.upf. The grader checks the edition and the forms of the commands you used, after Tcl substitution, excluding comments and unused text. It compares the intent with the old file's. Then it runs the old file's public scenario and two hidden ones.
Run checks the public scenario only and never accepts. Submit runs every row. OpenPA is our open power-aware tool: it reads the UPF, writes a power-aware copy of the RTL, and Icarus runs that copy.