W4.7.2 Fix the Sense and the Location

EasyFixOpenPA + Icarus · serverReview the topic

Repair an active-low isolation control and a released bus, while preserving the requested location metadata.

Hardware context: A switched core with zero, one, latched and released outputs. Keep powered receivers safe using correctly powered and controlled isolation.

Repair an active-low isolation control and a released bus, while preserving the requested location metadata.

The RTL contains no isolation cells. Your UPF adds them at the selected paths. Read the contract table before editing.

The supplied UPF file already defines the domains and their supplies. Keep that file loaded.

Full specification
RequirementContract
ControlEvery cell uses iso_n, active low.
Local outputPort a clamps to 0; request self.
Parent outputPort b clamps to 1; request parent.
Shared bus driverPort z releases its output with Z; request fanout. This is an output driver, not an inout port.
Legacy automatic requestPort c clamps to 0; preserve automatic as an OpenPA compatibility request.
Legacy sibling requestPort spare clamps to 1; preserve sibling as an OpenPA compatibility request.
Supplies and extentAll cells use AON; isolate outputs only. Keep the provided domains and supplies.

Simulator note: OpenPA checks requested location metadata. Its simulation rewrites connections in the parent; this task does not prove physical placement.

What the Grader Checks

OpenPA reads your file. A refusal ends the check with OpenPA's message and line. Otherwise every row below must pass.

RowRule
Data, isolation and supply sequencepublic scenario: Run shows it
Additional sequence Bhidden scenario
Additional sequence Chidden scenario
Intent equals the referencethe domain of every instance; the primary supply of every domain; supply ports, nets and their connections; isolation cells (clamp, enable, sense, supply); where each isolation cell is placed
Power cellsat most 5

The Design

The power-unaware RTL your UPF describes (top boundary_soc). Open a file to read it.

island.sv
module island(input logic [4:0] d, output wire a, b, c, z, spare);
  assign a=d[0]; assign b=d[1]; assign c=d[2]; assign z=d[3]; assign spare=d[4];
endmodule
module boundary_soc(input logic [4:0] d, input logic iso, iso_n,
  output wire a,b,c,z,spare);
  island u_tx(.d(d),.a(a),.b(b),.c(c),.z(z),.spare(spare));
endmodule

Given UPF Files

Your file may load these with load_upf. The grader uses the same text.

boundary.upf
upf_version 4.0
set_design_top boundary_soc
create_power_domain PD_TOP -include_scope
create_power_domain PD_TX -elements {u_tx}
create_supply_port VA -direction in
create_supply_port VT -direction in
create_supply_port VG -direction in
create_supply_net NA
create_supply_net NT
create_supply_net NG
connect_supply_net NA -ports {VA}
connect_supply_net NT -ports {VT}
connect_supply_net NG -ports {VG}
create_supply_set AON -function {power NA} -function {ground NG}
create_supply_set TX -function {power NT} -function {ground NG}
associate_supply_set AON -handle PD_TOP.primary
associate_supply_set TX -handle PD_TX.primary

The Public Scenario

Data, isolation and supply sequence. Run checks its output and shows the expected lines and any failure.

tb.sv (public scenario)
`timescale 1ns/1ps
module tb;
 import UPF::*;
 logic [4:0] d=0; logic iso=0, iso_n=1;
 wire a,b,c,z,spare;
 boundary_soc dut(.*);
 task show(input string s); $display("%s a=%b b=%b c=%b z=%b spare=%b",s,a,b,c,z,spare); endtask
 initial begin
 void'(supply_on("VA",1.0)); void'(supply_on("VT",1.0)); void'(supply_on("VG",0.0));
 #5;
 d=5'b01010; #2; show("live"); iso_n=0; #2; show("isolated"); void'(supply_off("VT")); #2; show("off");
 #5; $finish;
 end
endmodule

Examples

Example 1

The Starter Report
Input
The starter UPF, read by OpenPA
OpenPA reports (recorded)
Strategies
  set_isolation LOCAL (answer.upf:2): clamp 0, enable iso_n active high, supply AON, location self
  set_isolation PARENT (answer.upf:3): clamp 1, enable iso_n active high, supply AON, location parent
  set_isolation BUS (answer.upf:4): clamp 0, enable iso_n active high, supply AON, location self
  set_isolation OLD_AUTO (answer.upf:5): clamp 0, enable iso_n active high, supply AON, location automatic
  set_isolation OLD_SIB (answer.upf:6): clamp 1, enable iso_n active high, supply AON, location sibling

Read the report before making the first edit.

Example 2

Before Adding Strategies
Input
The supplied domains and rails, without isolation strategies
OpenPA reports (recorded)
Strategies

Supply wiring alone does not insert isolation.

Example 3

The Sample Sequence
Input
The reference UPF on the public bench
The bench prints (recorded)
live a=0 b=1 c=0 z=1 spare=0
isolated a=0 b=1 c=0 z=z spare=1
off a=0 b=1 c=0 z=z spare=1

Data passes while isolation is inactive. The later rows exercise the output contract.

Constraints and Contract

  • Submit the complete UPF answer. Keep the provided load_upf command.
  • Use the signals and supply sets named in the table. Hidden sequences change data and control timing.

Hints

Hint 1

Trace the driver and each receiver separately. A port name and an instance name have different precedence.

Hint 2

Check active polarity before changing the clamp value. Inspect the static report as well as the output.

Hint 3

Start with the transparent case, then assert isolation before switching off a rail.

What the grader checks: The judge checks power intent and simulated values. Location metadata is checked, but physical placement and port attributes are outside this model.

Run checks the public scenario only and never accepts. Submit runs every row. OpenPA is our open power-aware tool: it reads the UPF, writes a power-aware copy of the RTL, and Icarus runs that copy.

See all 2 problems on this path
Your UPF file UPFSaved locally
Ln 1, Col 1Tab indents · Ctrl/⌘ + Enter runs
Not run yet

Run checks the public scenario. Submit checks every row in the description.

OpenPA + Icarus · server