P11.12.1 Why 64 Bytes?

EasyDebugIcarus Verilog · serverReview the topic

A half-duplex station loses frames on a long wire, and its own collision counter never moves. Find the first bad cycle, and name the bug.

Hardware context: An Ethernet MAC and physical coding sublayer: frame builder and checker, reconciliation sublayer and block encoder. Build, check and pace Ethernet frames, and code them for the physical layer as IEEE 802.3 specifies.

Station A shares a wire with station B. The wire is 22 octet times long, one way. A sends a short frame, and B starts a frame of its own just before A's signal reaches it.

The log says: ERROR: A reports its frame sent, but it met B's signal at B. The frame is lost.

Step 1: find the first cycle where one of A's signals differs from a correct transmitter, and name it. Step 2: choose the cause from four bugs. Each is real and fails at a different cycle.

Step 3 is optional: fix the transmitter and run the tests.

Signals in the Timeline

SignalWidthRole
test_number8input of each check
Full specification
The transmitter API
function automatic void tx_reset();
function automatic void tx_load(input int frame_octets);   // DA to FCS, before padding
function automatic bit tx_tick(input bit carrier, input int r);  // one octet time; r: the backoff draw in slots
RuleCorrect transmitter (octet times)
Deferencewait while the wire is busy, then 12 quiet octet times (96 bit times). A bench rule: the standard restarts only the first part of the gap, and then transmits whatever the carrier
Packet8 octets of preamble and SFD, then the frame padded to at least 64 octets
Collisioncarrier while sending: count it, send 4 octets of jam (32 bits)
Backoffafter the jam wait r × 64 octet times; r is the draw the bench passes in
Give upafter 16 collisions
state0 idle, 1 defer, 2 send, 3 jam, 4 backoff, 5 sent, 6 gave up

Cycle N is the stretch where the cycle counter shows N. A signal is wrong in cycle N if its value there differs from a correct transmitter's.

Diagnose the Failing Run

The test below runs the buggy design. Read its log, then find where it first goes wrong in the waveform.

Log

Waveform

Click a signal at a cycle to select it. Or focus the waveform and use the arrow keys: Left and Right move one cycle, Up and Down one signal.

Step 1 · The first bad cycle and signal
Step 2 · The cause

Step 3 is optional: fix the code in the editor, then run the tests.

Examples

Example 1

A Quiet Wire
Input
random frames, long quiet stretches
Output
wrong_ticks = 0, ticks_in_hundreds = 30, first_wrong_tick = 0

Every octet time, A's output, state and collision count must equal a correct transmitter's.

Example 2

A Busy Wire
Input
many short gaps, so many collisions
Output
wrong_ticks = 0, ticks_in_hundreds = 60, first_wrong_tick = 0

Collisions, jams and backoffs happen often. Each must start and end on the right octet time.

Example 3

A Very Busy Wire
Input
nearly every gap short
Output
wrong_ticks = 0, ticks_in_hundreds = 200, first_wrong_tick = 0

Some frames collide many times. The backoff range and the attempt limit both matter here.

Constraints and Contract

  • Keep the three functions and the six variables.
  • The bench calls tx_tick once per octet time with the carrier that A hears.
  • Time is counted in octet times; one slot is 64.
  • Off limits: the names rng, tb, root, names that begin with ref_ and the modules of the bench.

Hints

Hint 1

How long should A's packet be for a 30-octet frame? In which cycle should it end?

Hint 2

When does B's signal reach A? Is A still sending then?

Hint 3

The slot is 64 octet times for a reason: compare it with the round trip of 44.

What the grader checks: The failing run is simulated live with the faulty transmitter. The first bad cycle and each option's symptom come from runs of each version on the same bench. The optional fix is checked against a private reference transmitter at every octet time. The tests cover 69,000 octet times of random traffic. They include a storm where nine frames collide 16 times; its draws are 7 slots at most. Octet-time units are a bench choice.

6 checks on Icarus Verilog · server. Run the examples first, then check the full regression. Full checks use the server judge. Downloads contain your source only; samples require the simulation service. A passing result establishes the tested cases, not a proof for all possible inputs.

See all 2 steps and the final capstone

Report a problem with this page

Your code SystemVerilogSaved locally
Ln 1, Col 1Tab indents · Ctrl/⌘ + Enter runs samples
Not run yet

A Quiet Wire

Input
random frames, long quiet stretches
Expected output
wrong_ticks = 0, ticks_in_hundreds = 30, first_wrong_tick = 0

Every octet time, A's output, state and collision count must equal a correct transmitter's.

Run samples executes all 3 public checks. Check all tests runs 6 checks on the server.